{"id":2097,"date":"2026-11-29T20:47:06","date_gmt":"2026-11-29T20:47:06","guid":{"rendered":"https:\/\/cibersistemas.pt\/en\/uncategorized\/who-invented-modbus-protocol\/"},"modified":"2026-11-29T20:49:18","modified_gmt":"2026-11-29T20:49:18","slug":"who-invented-modbus-protocol","status":"publish","type":"post","link":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/","title":{"rendered":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication"},"content":{"rendered":"<div class=\"cs-lang-links\" style=\"margin:0 0 22px;padding:10px 14px;background:rgba(127,127,127,.08);border-radius:6px;font-size:15px\">\n<p style=\"margin:0\">Read this article in: <a href=\"https:\/\/cibersistemas.pt\/tecnologia\/quem-inventou-protocolo-modbus\/\" hreflang=\"pt-BR\" lang=\"pt-BR\">Portuguese (Portugu\u00eas)<\/a> \u00b7 <a href=\"https:\/\/cibersistemas.pt\/es\/tecnologia\/quien-invento-protocolo-modbus\/\" hreflang=\"es\" lang=\"es\">Spanish (Espa\u00f1ol)<\/a><\/p>\n<\/div>\n<p>The <strong class=\"protocol\">Modbus protocol<\/strong> is recognized as one of the most fundamental and widely used communication languages in modern industry. More than just a technical standard, it has established itself as an essential <em class=\"fieldbus\">fieldbus<\/em> for exchanging information between various industrial electronic devices. Originally conceived for use with programmable logic controllers (PLCs), Modbus quickly transcended its initial niche, becoming a de facto standard in automation and monitoring systems. Its popularity is sustained by crucial features, such as being an open and royalty-free protocol, which greatly facilitates its adoption in complex factory environments.<\/p>\n<p>The history of Modbus is marked by continuous evolution and changes in ownership that have ensured its longevity and stability. The protocol was first published in 1979 by Modicon. Over time, the management and development of the standard underwent significant changes: in 1997, Modicon was acquired by Schneider Electric, and in 2004, the rights were transferred to the Modbus Organization, Inc., a trade association of users and suppliers. This trajectory demonstrates a continuous commitment to keeping the technology relevant, whether it is used on serial lines or in variants like Modbus TCP\/IP.<\/p>\n<p>In this article, we will delve into the creation and consolidation trajectory of Modbus. We will begin by examining the historical context of its invention at Modicon and the subsequent transfer of ownership. Next, we will detail how the protocol works, exploring the client-server architecture that defines the transactions. Finally, we will address the different versions of Modbus\u2014serial, TCP\/IP, and other variants\u2014to understand the profound impact and legacy that this industrial communication has left on global automation.<\/p>\n<div class=\"key-takeaways\" style=\"border-left:4px solid #1a73e8;background:rgba(26,115,232,.06);padding:14px 20px;margin:22px 0;border-radius:6px\">\n<p><strong class=\"heading\">Key Points<\/strong><\/p>\n<ul>\n<li>Launched in 1979, Modbus emerged to solve the systemic incompatibility of proprietary solutions.<\/li>\n<li>The standard architecture is Master-Slave (Client-Server), where the Master initiates and sets the pace.<\/li>\n<li>The protocol supports the exchange of discrete data (on\/off) and analog numerical data.<\/li>\n<li>Ownership evolved from Modicon to Schneider Electric and, currently, to the Modbus Organization, Inc.<\/li>\n<li>There are variants such as Modbus Serial Line (RTU) and Modbus TCP\/IP, which use different transmission media.<\/li>\n<\/ul>\n<\/div>\n<h2>Modbus protocol in summary<\/h2>\n<figure class=\"wp-block-table\">\n<table style=\"width:100%;border-collapse:collapse;font-size:15px\">\n<tbody>\n<tr>\n<th scope=\"row\" style=\"text-align:left;padding:8px 12px;border-bottom:1px solid #e5e5e5;width:34%;vertical-align:top\">Status<\/th>\n<td style=\"padding:8px 12px;border-bottom:1px solid #e5e5e5\">Active<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"text-align:left;padding:8px 12px;border-bottom:1px solid #e5e5e5;width:34%;vertical-align:top\">Latest version<\/th>\n<td style=\"padding:8px 12px;border-bottom:1px solid #e5e5e5\">Modbus application protocol specification V1.1b3; April 26, 2012<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"text-align:left;padding:8px 12px;border-bottom:1px solid #e5e5e5;width:34%;vertical-align:top\">Organization<\/th>\n<td style=\"padding:8px 12px;border-bottom:1px solid #e5e5e5\">Modicon (1979\u20131997); Schneider Electric (1997\u20132004); Modbus Organization, Inc. (since 2004)<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"text-align:left;padding:8px 12px;border-bottom:1px solid #e5e5e5;width:34%;vertical-align:top\">Related standards<\/th>\n<td style=\"padding:8px 12px;border-bottom:1px solid #e5e5e5\">Modbus Serial Line Protocol; Modbus TCP\/IP<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\" style=\"text-align:left;padding:8px 12px;border-bottom:1px solid #e5e5e5;width:34%;vertical-align:top\">Domain<\/th>\n<td style=\"padding:8px 12px;border-bottom:1px solid #e5e5e5\">Fieldbus<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2>The historical context and creation at Modicon<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"margin:26px auto;text-align:center\"><img decoding=\"async\" alt=\"Historical context and creation at Modicon \u2014 Modbus protocol\" loading=\"lazy\" src=\"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/protocolo-modbus-o-contexto-historico-e-a-criacao-na-modi-054248.webp\" style=\"width:100%;height:auto;border-radius:8px\"\/><\/figure>\n<p>The emergence of Modbus was not merely the creation of a protocol, but rather the necessary technical response to a critical bottleneck in the growing complexity of industrial automation. In the 1970s, the factory environment was characterized by a proliferation of proprietary solutions. Each machine or equipment manufacturer used its own &#8220;language&#8221; for data exchange, which created a scenario of systemic incompatibility. Communication between Programmable Logic Controllers (PLCs) and field devices (such as sensors and actuators) was often a manual, inefficient, and extremely fragile process.<\/p>\n<p>It was in this context of fragmentation and integration difficulty that Modicon, the pioneering company, developed Modbus, which was released in 1979. The primary objective was to establish a simple, universal, and standardized communication language. Modbus solved the &#8220;translation&#8221; problem between systems by defining a set of commands and a data exchange structure that would function independently of the physical hardware, provided the devices followed the protocol.<\/p>\n<h3>The Modbus Architecture: Standardization and Control<\/h3>\n<p>To ensure this structured communication, Modbus established a clear operating model: the master-slave model, or, as it is more commonly called, client-server. In this model, the network&#8217;s stability is maintained by the Master (usually the PLC), which initiates and sets the pace of the communication. The Slave (the field device, such as a sensor or I\/O module) has no autonomy to start a conversation; it only responds when requested by the Master.<\/p>\n<p>This specification was not limited only to who speaks, but also to the type of information that is exchanged. The Modbus protocol defines commands for sending discrete data\u2014which represent digital inputs and outputs (on\/off)\u2014or for sending numerical data, which is essential for analog measurement. To better understand the evolution of communication standards, such as MQTT, check out who invented the MQTT protocol; this ability to handle different types of information within a single standard was a milestone for the industry.<\/p>\n<p>It is important to note that although Modicon was the original creator, the history of Modbus is marked by continuous evolution that ensured its longevity. After Modicon operated the protocol from 1979 to 1997, ownership was transferred to Schneider Electric, which managed it for another decade, until 2004. Starting in 2004, Modbus Organization, Inc. took over responsibility, ensuring that the protocol continued to develop, with the publication of specifications such as the Modbus application protocol specification V1.1b3 on April 26, 2012. This ownership trajectory demonstrates the lasting impact of Modbus as a fundamental pillar of field automation.<\/p>\n<p style=\"margin:22px 0 8px\"><strong>\ud83d\udd52 The Evolution of Modbus Ownership<\/strong><\/p>\n<ul class=\"cs-timeline\" style=\"list-style:none;margin:0 0 22px;padding:0 0 0 18px;border-left:3px solid rgb(26,115,232)\">\n<li style=\"margin:0 0 12px\"><strong>1979<\/strong> \u2014 Modicon releases Modbus, aiming to standardize industrial communication.<\/li>\n<li style=\"margin:0 0 12px\"><strong>1979\u20131997<\/strong> \u2014 The period during which Modicon operated the protocol.<\/li>\n<li style=\"margin:0 0 12px\"><strong>1997\u20132004<\/strong> \u2014 Ownership transferred to Schneider Electric.<\/li>\n<li style=\"margin:0 0 12px\"><strong>2004<\/strong> \u2014 A Modbus Organization, Inc. took responsibility for managing the protocol.<\/li>\n<li style=\"margin:0 0 12px\"><strong>April 26, 2012<\/strong> \u2014 Publication of the Modbus application protocol specification V1.1b3.<\/li>\n<\/ul>\n<h2>The Evolution and Ownership Transition<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"margin:26px auto;text-align:center\"><img decoding=\"async\" alt=\"Evolution and ownership transition \u2014 Modbus protocol\" loading=\"lazy\" src=\"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/protocolo-modbus-a-evolucao-e-a-transicao-de-propriedade-054248.webp\" style=\"width:100%;height:auto;border-radius:8px\"\/><\/figure>\n<p>The longevity and tremendous success of Modbus are not merely due to its technical architecture, but also to the rigorous process of management and ownership transition that ensured its global stability and accessibility. Since its launch, the protocol has gone through distinct phases of corporate ownership, each one crucial to its evolution and consolidation as an industrial communication standard. The journey begins with Modicon, the pioneering company that developed the protocol, laying the groundwork for what would become one of the most fundamental languages of automation.<\/p>\n<p>The first major milestone in this ownership history occurred in 1997. After nearly two decades of use and refinement, Modicon transferred the management of Modbus to Schneider Electric. This period, which spanned from 1997 to 2004, was vital for the protocol&#8217;s expansion in an increasingly complex industrial landscape. While communication technology evolved, much like the history of the IRC protocol, Modbus continued to be improved and integrated into new market demands, solidifying its position in the Fieldbus domain. It is important to note that even with the change of stewards, the focus remained on maintaining functionality and expanding the protocol&#8217;s variants, such as Modbus TCP\/IP, which allowed communication over wider networks.<\/p>\n<p>The second major transition, which occurred in 2004, marked a decisive turning point for the nature of Modbus. Ownership was transferred from Schneider Electric to Modbus Organization, Inc. This move was fundamental to ensuring that the protocol remained an open, non-proprietary standard. By being managed by a dedicated organization, Modbus gained an additional layer of governance, ensuring that its evolution was guided by the industrial community and not just by singular market interests. This independent management structure is what allows the protocol to remain relevant and stable to this day, with versions such as the Modbus application protocol specification V1.1b3, dated April 26, 2012, demonstrating its continuous maintenance and updates.<\/p>\n<p>This succession of ownership\u2014Modicon (1979\u20131997), followed by Schneider Electric (1997\u20132004), and finally, the Modbus Organization, Inc. (since 2004)\u2014was not merely a name change in a document. It was an ongoing process of ensuring continuity. Each transition ensured that Modbus remained a robust standard, capable of adapting to new technologies, such as the inclusion of related protocols like Modbus Serial Line Protocol and Modbus TCP\/IP, without losing the essence of its master-slave communication. This trajectory demonstrates a commitment to keeping Modbus a fundamental and open communication language for the global industry.<\/p>\n<h2>How the Protocol Works: The Client-Server Architecture<\/h2>\n<p>Modbus, in its operational essence, transcends the mere exchange of bits; it establishes a highly structured communication model, known as client-server (or, in its origin, master-slave). This architecture unequivocally defines who initiates the dialogue and who is responsible for providing the response. The <strong>Client<\/strong> is the proactive agent, the request initiator. It is the one that needs to read specific data or command a change in some system resource. On the other hand, the <strong>Server<\/strong> is the reactive agent. Its function is to listen, receive the Client&#8217;s request, process the requested information, and only then send the data or confirmation that the action was executed; to better understand other communication models, see who invented the XMPP protocol.<\/p>\n<p>The beauty and robustness of Modbus lie in the standardization of this transaction. When the Client sends a message, that message is not just a random set of numbers; it is encapsulated in a specific data unit, a <em>Protocol Data Unit<\/em> (PDU). The PDU is the information package that ensures the message is understood in its entirety by the Server. This unit contains, in addition to the data itself, crucial metadata, such as the address of the register being queried and the code that defines the request&#8217;s intent. It is this standardized structure that allows devices from different manufacturers, but which adhere to the same protocol, to communicate cohesively.<\/p>\n<div class=\"cs-box\" style=\"border-left:4px solid rgb(100,116,139);background:rgba(100,116,139,.07);padding:14px 20px;margin:22px 0;border-radius:6px\">\n<p style=\"margin:0 0 6px\"><strong>\ud83d\udcd8 PDU<\/strong><\/p>\n<p style=\"margin:0\">A Protocol Data Unit is the information packet that ensures the message is understood in its entirety by the Server. It contains the data and crucial metadata, such as the queried register address and the request code.<\/p>\n<\/div>\n<h3>How the Request Is Built<\/h3>\n<p>The most technical and defining element of a Modbus transaction is the Function Code ( Function Code ). If the Client only wants to know the value of a variable (for example, the temperature of a motor), it does not send a generic command; it sends a specific Function Code, such as &#8220;Read Coils&#8221; or &#8220;Read Registers.&#8221; This code is essentially the verb of the communication. It instructs the Server on the exact action that must be performed.<\/p>\n<p>To maintain protocol flexibility, Modbus establishes a classification for these codes. There are three main types:<\/p>\n<ul>\n<li>Public: Standardized and widely recognized codes used for basic operations (data reading and writing).<\/li>\n<li><strong>User-Defined:<\/strong> Codes created by engineers or companies for specific functionalities, allowing system customization.<\/li>\n<li><strong>Reserved:<\/strong> Codes reserved for future use by protocol development.<\/li>\n<\/ul>\n<p>In summary, the flow of a transaction is a precise dance: the Client, acting as the master, uses a specific Function Code within an PDU to request something; the Server, acting as the slave, interprets this code, accesses the corresponding internal data, and returns the information, closing the communication cycle. This clarity and technical rigor are what make Modbus such a reliable protocol, as specified in versions like V1.1b3, whose most recent specification was dated April 26, 2012.<\/p>\n<h2>The Different Versions: Serial, TCP\/IP, and Variants<\/h2>\n<figure class=\"wp-block-image size-large\" style=\"margin:26px auto;text-align:center\"><img decoding=\"async\" alt=\"The different versions: serial, TCP\/IP, and variants \u2014 Modbus protocol\" loading=\"lazy\" src=\"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/protocolo-modbus-as-diferentes-versoes-serial-tcp-ip-e-va-054248.webp\" style=\"width:100%;height:auto;border-radius:8px\"\/><\/figure>\n<p>The longevity and success of Modbus are not limited only to its logical architecture, but also to its ability to adapt over time. This adaptability resulted in the emergence of different protocol versions, the most prominent being Modbus Serial Line and Modbus TCP\/IP. Although both follow the client-server essence, they use fundamentally different transmission media: one focused on direct field communication (serial) and another designed for modern computer networks (Ethernet).<\/p>\n<h3>Modbus Serial Line: The Precision of Binary<\/h3>\n<p>Modbus RTU (Remote Terminal Unit) is currently one of the most common implementations. The RTU name refers to the transmission mode where addresses and values are represented in binary format. This format is characterized by being compact, meaning it uses fewer resources to transmit the same amount of data compared to other methods. In RTU mode, the word size is 8 bits. To ensure data integrity, the transmission of each message must include an error-checking mechanism known as Cyclic Redundancy Check (CRC). The CRC used is CRC-16-MODBUS. A notable technical feature of RTU is the way data is packaged: each byte transmitted is encoded in 11 bits, consisting of 1 start bit, 8 data bits (with the least significant bit sent first), 1 parity bit, and 1 stop bit. The standard parity is even parity.<\/p>\n<p>Serial transmission demands rigor: a Modbus RTU message must be transmitted continuously, without hesitation between characters, separated by idle periods. CRC-16-MODBUS is calculated to ensure data reliability during field communication, a critical factor in robust industrial environments.<\/p>\n<h3>Modbus TCP\/IP: Network Communication<\/h3>\n<p>In contrast to serial transmission, Modbus TCP\/IP is a variant designed to communicate over TCP\/IP networks. This version uses the Ethernet physical medium (IEEE 802.3) and connects specifically via port 502. The main difference in terms of data integrity is that Modbus TCP\/IP does not require an internal checksum calculation, as the lower layers of the network protocol already provide this protection. The Modbus TCP\/IP Application Data Unit (ADU) is structured by concatenating the Modbus Application Protocol header, the Function Code, and the Data.<\/p>\n<p>The ADU header contains the Unit Identifier, which is particularly useful in complex scenarios, such as when a Modbus TCP device is connected to a gateway that, in turn, communicates with a Modbus RTU device. The Modbus TCP\/IP frame structure is therefore more complex, but extremely efficient for network environments.<\/p>\n<h3>Bridging Worlds: Converters<\/h3>\n<p>In many installations, it is necessary to communicate between older devices that use Serial Modbus and modern systems based on TCP\/IP. In these cases, Modbus-TCP&lt;-&gt;Serial Modbus (RS-232\/485) converters come into play. It is crucial to understand that these devices are not merely physical converters of electrical signals; they are protocol implementations. They must translate Modbus data packets, which are encapsulated in TCP\/IP frames, to serial format, and vice versa.<\/p>\n<p>The function of these converters is highly sophisticated. They must interpret the Modbus packet, identify the destination slave address, and then send the data to the correct serial port, allowing communication to occur even if the physical interfaces and underlying protocols are completely different.<\/p>\n<p style=\"margin:22px 0 6px\"><strong>\ud83d\udcca Comparison: Modbus Serial vs. Modbus TCP\/IP<\/strong><\/p>\n<figure class=\"wp-block-table cs-tabela\" style=\"margin:0 0 22px;overflow-x:auto\">\n<table style=\"width:100%;border-collapse:collapse;font-size:15px\">\n<thead>\n<tr>\n<th style=\"padding:8px 12px;text-align:left;background:rgba(127,127,127,.12);border-bottom:2px solid rgba(127,127,127,.3)\">Feature<\/th>\n<th style=\"padding:8px 12px;text-align:left;background:rgba(127,127,127,.12);border-bottom:2px solid rgba(127,127,127,.3)\">Modbus Serial (RTU)<\/th>\n<th style=\"padding:8px 12px;text-align:left;background:rgba(127,127,127,.12);border-bottom:2px solid rgba(127,127,127,.3)\">Modbus TCP\/IP<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Transmission Medium<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Direct field communication (Serial)<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Computer networks (Ethernet)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Error Checking<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Requires CRC-16-MODBUS<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Protection provided by network layers<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Data Structure<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Binary, compact (8-bit word)<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">More complex (ADU with header)<\/td>\n<\/tr>\n<tr>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Transmission Requirement<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Continuous messages with inactivity<\/td>\n<td style=\"padding:8px 12px;border-bottom:1px solid rgba(127,127,127,.2);vertical-align:top\">Operates over TCP\/IP (Port 502)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n<h2>Impact and legacy in industrial automation<\/h2>\n<p>Modbus is not just a set of technical specifications; it is a pillar of global industrial control infrastructure. Its longevity and dominance as a &#8220;de facto standard&#8221; stem from a complex corporate trajectory and the inherent flexibility of its design. The protocol was born under the aegis of Modicon, going through different ownership phases\u2014from Modicon (1979\u20131997) to Schneider Electric (1997\u20132004), and more recently, to Modbus Organization, Inc. (since 2004). This institutional evolution, culminating in specifications such as the Modbus application protocol specification V1.1b3, dated April 26, 2012, demonstrates that Modbus has solidified itself as a mature system capable of supporting the complexity of such a dynamic sector as the oil and gas industry.<\/p>\n<h3>Design Resilience and Industrial Customization<\/h3>\n<p>One of the crucial factors in Modbus&#8217;s massive acceptance is its ability to be adapted to extremely specific industrial requirements. Although the base protocol is highly standardized, its structure has allowed for the development of specialized variants that meet critical market niches. Notable examples include Pemex Modbus, created for the oil and gas company Pemex, which added support for flow data and history, and Enron Modbus, which introduced support for floating-point and 32-bit integer variables, aligning with American Petroleum Institute (API) standards. It is important to note, however, that despite the similarity in data models, these extensions are not interoperable, and their <em>frame<\/em> formats are distinct, reflecting the highly specialized nature of each solution.<\/p>\n<p>In terms of implementation, Modbus stands out as a protocol that, while complex in its shared medium access operation (where collision resolution is the application&#8217;s responsibility), offers a robust and low operational cost architecture. Unlike fully proprietary systems, the open model of Modbus allowed it to spread rapidly, making it accessible to a vast range of engineers and companies. This accessibility and the absence of a strict <em>royalty<\/em> monopoly contributed significantly to its consolidation as the universal language of communication in many factories and refineries.<\/p>\n<h3>Legacy in SCADA and RTU Systems<\/h3>\n<p>The most tangible legacy of Modbus lies in its fundamental role in the integration between the field and the office. It is the preferred communication mechanism for connecting Remote Terminal Units (RTUs)\u2014the devices physically on the factory floor\u2014to data acquisition and control systems (SCADA). SCADA, in turn, is the supervisory system that collects, stores, and monitors the information. Modbus&#8217;s ability to maintain this stable and structured link, whether through serial implementation (Modbus RTU) or the TCP\/IP variant, ensures that data collected by sensors and actuators is reliably transmitted to the decision-making centers. Thus, Modbus is not just a protocol; it is the backbone of automated operation, allowing control to be exercised remotely and with precision.<\/p>\n<div class=\"cs-box\" style=\"border-left:4px solid rgb(26,115,232);background:rgba(26,115,232,.07);padding:14px 20px;margin:22px 0;border-radius:6px\">\n<p style=\"margin:0 0 6px\"><strong>\ud83d\udccc What Makes Modbus a Successful Standard?<\/strong><\/p>\n<ul style=\"margin:0;padding-left:22px\">\n<li>Flexible design that allows for niche customizations.<\/li>\n<li>Open model that facilitated rapid global dissemination.<\/li>\n<li>Low operational cost compared to proprietary systems.<\/li>\n<li>A pillar in the integration between the factory floor and the office.<\/li>\n<\/ul>\n<\/div>\n<h2>Glossary<\/h2>\n<ul class=\"cs-glossario\">\n<li><strong>Fieldbus<\/strong>: This is the industrial communication domain where Modbus operates, connecting field devices such as sensors and actuators.<\/li>\n<li><strong>Master-Slave<\/strong>: An operating model where the Master (Client) initiates communication and the Slave (Server) only responds when requested.<\/li>\n<li><strong>PDU<\/strong>: Protocol Data Unit; the information packet that encapsulates the message, containing crucial data and metadata.<\/li>\n<li><strong>CRC<\/strong>: Cyclic Redundancy Check; an error-checking mechanism used to ensure the integrity of transmitted data.<\/li>\n<li><strong>RTU<\/strong>: Remote Terminal Unit; a serial transmission mode where addresses and values are represented in compact binary format.<\/li>\n<li><strong>TCP\/IP<\/strong>: A variant of Modbus designed to communicate over modern computer networks, utilizing the Ethernet physical medium.<\/li>\n<\/ul>\n<h2>Frequently Asked Questions<\/h2>\n<details class=\"cs-faq\" style=\"border:1px solid rgba(127,127,127,.3);border-radius:6px;padding:10px 16px;margin:10px 0\">\n<summary style=\"cursor:pointer\">\n<h3 style=\"display:inline;font-size:1.05em;margin:0\">What is the main difference between Modbus RTU and Modbus TCP?<\/h3>\n<\/summary>\n<p style=\"margin:10px 0 0\">Modbus RTU focuses on field serial communication, using binary format and requiring an error-checking mechanism called CRC-16-MODBUS. Modbus TCP\/IP, on the other hand, operates on Ethernet networks and does not require internal checksum calculation, as the network layers already provide that protection.<\/p>\n<\/details>\n<details class=\"cs-faq\" style=\"border:1px solid rgba(127,127,127,.3);border-radius:6px;padding:10px 16px;margin:10px 0\">\n<summary style=\"cursor:pointer\">\n<h3 style=\"display:inline;font-size:1.05em;margin:0\">Is Modbus a proprietary or open-source protocol?<\/h3>\n<\/summary>\n<p style=\"margin:10px 0 0\">Although it was developed by a pioneering company, the management of the protocol was transferred to a dedicated organization. This succession of ownership ensures that Modbus remains an open standard, guided by the industrial community.<\/p>\n<\/details>\n<details class=\"cs-faq\" style=\"border:1px solid rgba(127,127,127,.3);border-radius:6px;padding:10px 16px;margin:10px 0\">\n<summary style=\"cursor:pointer\">\n<h3 style=\"display:inline;font-size:1.05em;margin:0\">What does &#8216;PLC&#8217; mean in the context of Modbus?<\/h3>\n<\/summary>\n<p style=\"margin:10px 0 0\">PLC, or Programmable Logic Controller, is typically the Master or Client in the Modbus architecture. It is the proactive agent that initiates the request for data or commands, maintaining network stability.<\/p>\n<\/details>\n<details class=\"cs-faq\" style=\"border:1px solid rgba(127,127,127,.3);border-radius:6px;padding:10px 16px;margin:10px 0\">\n<summary style=\"cursor:pointer\">\n<h3 style=\"display:inline;font-size:1.05em;margin:0\">Why is Modbus considered a de facto standard in the industry?<\/h3>\n<\/summary>\n<p style=\"margin:10px 0 0\">It established a simple and universal communication language, solving the problem of fragmentation caused by proprietary solutions. This allows devices from different manufacturers to communicate cohesively.<\/p>\n<\/details>\n<details class=\"cs-faq\" style=\"border:1px solid rgba(127,127,127,.3);border-radius:6px;padding:10px 16px;margin:10px 0\">\n<summary style=\"cursor:pointer\">\n<h3 style=\"display:inline;font-size:1.05em;margin:0\">What is a PDU in a Modbus transaction?<\/h3>\n<\/summary>\n<p style=\"margin:10px 0 0\">PDU, or Protocol Data Unit, is the package of information that ensures the message is understood in its entirety. This unit contains the data itself, as well as crucial metadata, such as the register address and function code.<\/p>\n<\/details>\n<h2>Conclusion<\/h2>\n<p>Modbus transcends the definition of a mere communication protocol; it represents a crucial architectural solution for the growing complexity of industrial automation. Born in the 1970s, in a scenario of intense fragmentation where each manufacturer used a proprietary &#8220;language,&#8221; Modbus, created by Modicon in 1979, established a universal and standardized language. By defining the client-server (master-slave) model and standardizing data exchange\u2014whether in discrete or numerical commands\u2014the protocol solved the bottleneck of systemic incompatibility, allowing devices from different manufacturers to operate in cohesive harmony.<\/p>\n<p>The longevity and robustness of Modbus are a testament not only to its technical design but also to a rigorous governance process. The protocol&#8217;s journey is marked by successive ownership changes\u2014moving from Modicon to Schneider Electric (1997\u20132004) and, subsequently, to Modbus Organization, Inc. (as of 2004). Each transition ensured that Modbus remained an open standard and evolved, incorporating vital variants such as Modbus TCP\/IP. This continuous management trajectory ensures that Modbus remains a fundamental and stable pillar for global field communication.<\/p>\n<p>By understanding the history behind the protocol, we realize that Modbus is more than a set of bits; it is an engineering milestone that unified the factory floor. For the automation professional, thoroughly knowing its origin and evolution is essential to ensure maximum efficiency and system integration. May this historical understanding inspire the continuous pursuit of optimization and excellence in every industrial project.<\/p>\n<h2>Sources and References<\/h2>\n<ul>\n<li><a href=\"https:\/\/en.wikipedia.org\/wiki\/Modbus\" rel=\"noopener\" target=\"_blank\">Modbus \u2014 Wikipedia<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it&#8230;<\/p>\n","protected":false},"author":1,"featured_media":2096,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_cs_gerador_v2":"","fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[4],"tags":[],"class_list":["post-2097","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technology"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt<\/title>\n<meta name=\"description\" content=\"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt\" \/>\n<meta property=\"og:description\" content=\"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/\" \/>\n<meta property=\"og:site_name\" content=\"Cibersistemas.pt\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/cibersistemas.pt\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/cibersistemas.pt\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-29T20:47:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-29T20:49:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1280\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Ant\u00f3nio C\u00e9sar de Andrade\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ant\u00f3nio C\u00e9sar de Andrade\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"17 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/\"},\"author\":{\"name\":\"Ant\u00f3nio C\u00e9sar de Andrade\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#\\\/schema\\\/person\\\/ea20c50a8d8bdbbb01ccc60e371a27b8\"},\"headline\":\"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication\",\"datePublished\":\"2026-11-29T20:47:06+00:00\",\"dateModified\":\"2026-11-29T20:49:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/\"},\"wordCount\":3351,\"publisher\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/protocolo-modbus-054248.webp\",\"articleSection\":[\"Technology\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/\",\"name\":\"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/protocolo-modbus-054248.webp\",\"datePublished\":\"2026-11-29T20:47:06+00:00\",\"dateModified\":\"2026-11-29T20:49:18+00:00\",\"description\":\"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/protocolo-modbus-054248.webp\",\"contentUrl\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/protocolo-modbus-054248.webp\",\"width\":1280,\"height\":720,\"caption\":\"Modbus protocol - MODBUS communication stack\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/technology\\\/who-invented-modbus-protocol\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/\",\"name\":\"Cibersistemas.pt\",\"description\":\"Cibersistemas.pt is a news portal about gaming and technology, with dozens of quality articles every day, in English.\",\"publisher\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#organization\",\"name\":\"Cibersistemas.pt\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Logo-Cibersistemas.jpg\",\"contentUrl\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/Logo-Cibersistemas.jpg\",\"width\":400,\"height\":400,\"caption\":\"Cibersistemas.pt\"},\"image\":{\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/cibersistemas.pt\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCcWHF3Q9kv7IXgdFuy1LB9A\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/#\\\/schema\\\/person\\\/ea20c50a8d8bdbbb01ccc60e371a27b8\",\"name\":\"Ant\u00f3nio C\u00e9sar de Andrade\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/cibersistemas.pt\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/antonio-cesar-de-andrade.jpg\",\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/antonio-cesar-de-andrade.jpg\",\"contentUrl\":\"https:\\\/\\\/cibersistemas.pt\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/antonio-cesar-de-andrade.jpg\",\"caption\":\"Ant\u00f3nio C\u00e9sar de Andrade\"},\"description\":\"A Portuguese professional with more than 20 years of experience in the technology world, he is the editor-in-chief of Cibersistemas PT, leading its editorial strategy and content production. A technology specialist and enthusiast, he follows trends in Artificial Intelligence, programming, software development, hardware, digital design and video games, with a focus on quality, credibility and the sharing of knowledge. Follow: LinkedIn \u00b7 Facebook \u00b7 Instagram \u00b7 YouTube \u00b7 Pinterest. Email: antonio.cesar@cibersistemas.pt\",\"sameAs\":[\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/\",\"https:\\\/\\\/www.facebook.com\\\/cibersistemas.pt\",\"https:\\\/\\\/www.instagram.com\\\/cibersistemas\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ant%C3%B3nio-c%C3%A9sar-andrade-a19063450\\\/\",\"https:\\\/\\\/pt.pinterest.com\\\/cibersistemas\\\/\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCcWHF3Q9kv7IXgdFuy1LB9A\\\/\"],\"url\":\"https:\\\/\\\/cibersistemas.pt\\\/en\\\/author\\\/antonio-cesar-de-andrade\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt","description":"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/","og_locale":"en_US","og_type":"article","og_title":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt","og_description":"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...","og_url":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/","og_site_name":"Cibersistemas.pt","article_publisher":"https:\/\/www.facebook.com\/cibersistemas.pt","article_author":"https:\/\/www.facebook.com\/cibersistemas.pt","article_published_time":"2026-11-29T20:47:06+00:00","article_modified_time":"2026-11-29T20:49:18+00:00","og_image":[{"width":1280,"height":720,"url":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp","type":"image\/webp"}],"author":"Ant\u00f3nio C\u00e9sar de Andrade","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Ant\u00f3nio C\u00e9sar de Andrade","Est. reading time":"17 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#article","isPartOf":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/"},"author":{"name":"Ant\u00f3nio C\u00e9sar de Andrade","@id":"https:\/\/cibersistemas.pt\/en\/#\/schema\/person\/ea20c50a8d8bdbbb01ccc60e371a27b8"},"headline":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication","datePublished":"2026-11-29T20:47:06+00:00","dateModified":"2026-11-29T20:49:18+00:00","mainEntityOfPage":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/"},"wordCount":3351,"publisher":{"@id":"https:\/\/cibersistemas.pt\/en\/#organization"},"image":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#primaryimage"},"thumbnailUrl":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp","articleSection":["Technology"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/","url":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/","name":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication - Cibersistemas.pt","isPartOf":{"@id":"https:\/\/cibersistemas.pt\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#primaryimage"},"image":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#primaryimage"},"thumbnailUrl":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp","datePublished":"2026-11-29T20:47:06+00:00","dateModified":"2026-11-29T20:49:18+00:00","description":"Discover the origin of Modbus. Understand how this industrial communication protocol, created by Modicon, became a global standard and how it...","breadcrumb":{"@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#primaryimage","url":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp","contentUrl":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/protocolo-modbus-054248.webp","width":1280,"height":720,"caption":"Modbus protocol - MODBUS communication stack"},{"@type":"BreadcrumbList","@id":"https:\/\/cibersistemas.pt\/en\/technology\/who-invented-modbus-protocol\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cibersistemas.pt\/en\/"},{"@type":"ListItem","position":2,"name":"Who Invented the Modbus Protocol? Modbus: History of Industrial Communication"}]},{"@type":"WebSite","@id":"https:\/\/cibersistemas.pt\/en\/#website","url":"https:\/\/cibersistemas.pt\/en\/","name":"Cibersistemas.pt","description":"Cibersistemas.pt is a news portal about gaming and technology, with dozens of quality articles every day, in English.","publisher":{"@id":"https:\/\/cibersistemas.pt\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cibersistemas.pt\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/cibersistemas.pt\/en\/#organization","name":"Cibersistemas.pt","url":"https:\/\/cibersistemas.pt\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cibersistemas.pt\/en\/#\/schema\/logo\/image\/","url":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/Logo-Cibersistemas.jpg","contentUrl":"https:\/\/cibersistemas.pt\/en\/wp-content\/uploads\/2026\/11\/Logo-Cibersistemas.jpg","width":400,"height":400,"caption":"Cibersistemas.pt"},"image":{"@id":"https:\/\/cibersistemas.pt\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/cibersistemas.pt","https:\/\/www.youtube.com\/channel\/UCcWHF3Q9kv7IXgdFuy1LB9A"]},{"@type":"Person","@id":"https:\/\/cibersistemas.pt\/en\/#\/schema\/person\/ea20c50a8d8bdbbb01ccc60e371a27b8","name":"Ant\u00f3nio C\u00e9sar de Andrade","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/antonio-cesar-de-andrade.jpg","url":"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/antonio-cesar-de-andrade.jpg","contentUrl":"https:\/\/cibersistemas.pt\/wp-content\/uploads\/2026\/11\/antonio-cesar-de-andrade.jpg","caption":"Ant\u00f3nio C\u00e9sar de Andrade"},"description":"A Portuguese professional with more than 20 years of experience in the technology world, he is the editor-in-chief of Cibersistemas PT, leading its editorial strategy and content production. A technology specialist and enthusiast, he follows trends in Artificial Intelligence, programming, software development, hardware, digital design and video games, with a focus on quality, credibility and the sharing of knowledge. Follow: LinkedIn \u00b7 Facebook \u00b7 Instagram \u00b7 YouTube \u00b7 Pinterest. Email: antonio.cesar@cibersistemas.pt","sameAs":["https:\/\/cibersistemas.pt\/en\/","https:\/\/www.facebook.com\/cibersistemas.pt","https:\/\/www.instagram.com\/cibersistemas","https:\/\/www.linkedin.com\/in\/ant%C3%B3nio-c%C3%A9sar-andrade-a19063450\/","https:\/\/pt.pinterest.com\/cibersistemas\/","https:\/\/www.youtube.com\/channel\/UCcWHF3Q9kv7IXgdFuy1LB9A\/"],"url":"https:\/\/cibersistemas.pt\/en\/author\/antonio-cesar-de-andrade\/"}]}},"_links":{"self":[{"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/posts\/2097","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/comments?post=2097"}],"version-history":[{"count":1,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/posts\/2097\/revisions"}],"predecessor-version":[{"id":2098,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/posts\/2097\/revisions\/2098"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/media\/2096"}],"wp:attachment":[{"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/media?parent=2097"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/categories?post=2097"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/cibersistemas.pt\/en\/wp-json\/wp\/v2\/tags?post=2097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}